您好!籨ui梦蔴ang州万达娱le注册ping台denglu消防安全设备有限公司!
zhuan业气体消防设备智能消防解决方案zhuan业gong应shang打造中国zui好的气体消防设备gong应shang
全国统一ke服热线0571-88212867
lianxi

hang州万达娱le注册ping台denglu消防安全设备有限公司
电话:0571-88212867
传真:0571-88210907
di謋a篽ang州市yuhangqu闲林镇裕丰路7号
当前位zhi : 首页 > 业na新闻

435manbetx

发表shi间 : 2019-07-03 * 浏览 : 847

  消防设jishen核shi早期匹配过cheng中一个复杂、困nan、长期的过cheng。由于消防dui与建设xiangmuyongdigui划部门属于ping行部门,有些shou续ke以并行办理。对早期匹配工cheng师的建议shi尽早与消防dui沟通,并在tiaojian允xu的情况xia提前jian查tuzhi。为了避免不均匀的工序和无法开始施工。


  《中华ren民共和国消防法》di十一tiao:大型ren员密集场所和国务院公安部门gui定的其他特謟hiㄉ鑨iangmu,建设单位应当向公安机关消防机gou报送消防设jiwenjian。gongshen核。

  《中华ren民共和国消防法》di十二tiao:yi法应当经公安机关消防机goushen簊huo慕ㄖheng,由shen批该建筑工cheng施工xuke证的部门不得发给施工xuke证,并不得施工。建筑施工单位和施工单位不得施工;yi经取得施工xuke证的其他建筑工cheng,应当yi法进行抽查。未竣工的,停止施工。

  以shangliangtiao引自《中华ren民共和国消防法》。消防设jishen核主要zhen对建筑、给pai水、电气等zhuan业。萮uan诿挥邢郎鑚ishen簊huo那榭鰔ia,桩ji工chengshi不允xu建造的。否则,jiang对施工单位和施工单位处以fa款。

  在这里,消防设jishen核shizhen对建筑施工xiangmu,根据wo自己的经验,ke以分为空白类型、精zhuang类型liang种类型,这意味着当干燥祄u瞻追kao鋢u要为消防设jishen核申报shi,当完成空白穔ao鋝hi,huaixu要申报消防设jishen核以进行精细zhuang修。(有ping方米限制,低于300_或投资)。不xu要处理30万ren以xia的ren员,但如果ren员拥挤的di方,不xu要处理,直到200ren以xia)。验收过cheng中,未进行消防设jishen核和申报工作的,不予验收。向当di消防dui申报yi完成蚻iangㄏ郎鑚ishen核和精zhuang消防设jishen核后,ke进行逐级验收(先蚻iangê缶珃huang)和蚻iangň珃huang的统一验收。(俗称liang报一kao)

  认真dishuo,xia面shi如何进行消防设jishen簊huo募蛞猻huoming:

  1、处理的前提tiaojian:

  2、取得建设工chenggui划xuke证。

  3、获得ditujian查证shu。

  4、获得消防通知。

  5、完成建筑、jiegou、管dao和电气tuzhi和wenjian的设ji。(zhuang饰zhuang修tu设ji)

  6、加工要求:

  7、《建筑工cheng消防设jishen核申报表》(以xia简称:消防dui以xia5000,消防dui以shang5000,特别shizhong大工chengxu要消防dui处理)、《小型工cheng消防设jishen核记lu表》、《大型工cheng消防设jishen核表》形式

  henming显,注意力的chengdushi不tong的…注ang莑u表shi直接办理竣工tu的提gong,以取得记lu证shu,但设jishen核表xu要完善资料,报当di消防dui报建,竣工tushen核合格后,ke在设ji奥迪完成后出具tuzhishen核。T证shu…

  8、liang份营业执照和zu织机goudai码证。(盖建设单位章)

  9、法ren身份证、授权委tuoshu、shoutuoren身份证。(盖建设单位章)

  10、建筑工chenggui划xuke证(精zhuang修消防设jishen核huaixu提gong民yong消防设jishen核证shu)

  11、设ji单位和tuzhishen查单位的zu织机goudai码证、营业执照,设ji单位和tuzhishen查ren员的单位资格证(分别加盖设ji单位、tuzhishen查机gou和施工单蝖uai?单位)各liang份。

  12、完整的zhuan业tuzhi

  13、外部热输入设jishi践


Fire design audit is a complex, difficult and long-term process in the early matching process. Because the fire brigade and the land planning department of construction projects belong to parallel departments, some procedures can be handled concurrently. The suggestion for early matching engineers is to communicate with the fire brigade as soon as possible and check the drawings in advance if conditions permit. In order to avoid uneven work procedures and inability to start construction.

Article 11 of the Fire Protection Law of the People's Republic of China: For large-scale personnel-intensive places and other special construction projects stipulated by the public security department under the State Council, the construction unit shall submit fire protection design documents to the fire control institutions of public security organs. For review.

Article 12 of the Fire Protection Law of the People's Republic of China: Construction projects that should be examined and verified by fire control agencies of public security organs according to law shall not be granted construction permits or constructed by the departments that examine and approve the construction permits of such construction projects. Construction units and construction units shall not construct; other construction projects that have obtained construction permits shall be subject to spot checks according to law. If the project is not completed, the construction shall be stopped.

The above two are quoted from the Fire Protection Law of the People's Republic of China. Fire design audit is mainly aimed at building, water supply and drainage, electrical and other specialties. However, in the absence of fire design audits, pile foundation engineering is not allowed to be constructed. Otherwise, the construction unit and the construction unit will be fined.

Here, fire design audit is for building construction projects. According to my own experience, it can be divided into two types: blank type and hardcover type. This means that when dry blank room needs to be declared for fire design audit, when the blank room is completed, it also needs to declare fire design audit for fine decoration. 。 (There is a square metre limit, less than 300 or investment). There is no need to deal with people under 300,000, but if there are crowded places, there is no need to deal with them until 200 people or less. In the process of acceptance, those who fail to check and declare fire control design shall not be accepted. After declaring to the local fire brigade that the civil fire protection design audit and the hardcover fire protection design audit have been completed, the step-by-step acceptance (first civil construction and then hardcover) and the unified acceptance of the civil hardcover can be carried out. (commonly known as two newspapers and one examination)

Seriously speaking, the following is a brief description of how to conduct fire design audits:

1. Prerequisites for processing:

2. Obtain construction project planning license.

3. Obtain the map inspection certificate.

4. Get fire control notice.

5. Complete the design of building, structure, pipeline and electrical drawings and documents. (Decoration design)

6. Processing requirements:

7. Fire Design Audit Declaration Form for Construction Engineering (hereinafter referred to as: Fire Brigade below 5000, Fire Brigade above 5000, especially major projects need fire brigade processing), "Fire Design Audit Record Form for Small-scale Engineering" and "Fire Design Audit Form for Large-scale Engineering" forms

Obviously, the degree of attention varies. Note: Record sheet is to provide the completed drawings directly to obtain the record certificate, but the design audit sheet needs to improve the information and report to the local fire brigade for construction. When the completed drawings are qualified, the drawings can be issued after the completion of the design auditing by Audi. T certificate...

8. Two business licenses and organization code certificates. (Stamp of Construction Unit)

9. Legal person identity card, power of attorney and trustee identity card. (Stamp of Construction Unit)

10. Construction Engineering Planning License (Civil Fire Design Audit Certificate is also required for fire design audit of fine decoration)

11. Two copies of the organization code certificate, business license of the design unit and the drawing examination unit, and the unit qualification certificate of the design unit and the drawing examination personnel (with the official seal of the design unit, the drawing examination organization and the construction unit respectively).

12. Complete professional drawings

13. Design Practice of External Heat Input


shang一tiao:消防设备月du,季dujian测gui范 xia一tiao: 没有了